200 GPD Osmotic Membrane AC-OM-200 Water Filter Reverse Osmosis EFFICIENT
The AC-OM-200 osmotic membrane with a capacity of 200 GPD (approximately 760 liters per day) is a key component for reverse osmosis sys Read moreShow less
The AC-OM-200 osmotic membrane with a capacity of 200 GPD (approximately 760 liters per day) is a key component for reverse osmosis systems. It provides high filtration efficiency of up to 99% of contaminants, including heavy metals, nitrates, pesticides, and microorganisms. It fits most standard RO installations, and its replacement is straightforward. It is recommended to use pre-filters that remove chlorine (tolerance 0 ppm).
Benefits
Specifications
- Membrane capacity
- 200 GPD
- Application
- Small business
- Compatibility
- Universal RO systems
- Service life
- 60 months
- Maximum working pressure
- 6 bar
- Maximum working temperature
- 45 °C
View full specifications
- Membrane size
- 1812
- Minimum working pressure
- 2.8 bar
- Minimum working temperature
- 4 °C
- Model
- AC-OM-200
- Product type
- RO membrane
Description
The 200 GPD AC-OM-200 osmotic membrane is an efficient cartridge for reverse osmosis systems, designed for effective water treatment at home and in the office. This osmotic filter supports the daily operation of RO installations, ensuring high contaminant separation efficiency, a capacity of up to approximately 760 liters per day, and compatibility with most standard solutions using a reverse osmosis filter. It is a practical choice for anyone looking to obtain clean water for drinking and everyday use as part of a modern water filtration system.

Efficient membrane for RO systems
The AC-OM-200 osmotic membrane is a key element of filtration in reverse osmosis systems. It is responsible for the precise separation of unwanted substances from water, helping to achieve very good drinking water quality.
A capacity of 200 GPD means approximately 760 liters of water per day. This parameter works well in both home installations and office applications, where stable operation, an adequate amount of filtered water, and reliable performance matter.
Main benefits
- Advanced filtration technology – removes up to 99% of contaminants, including bacteria, viruses, heavy metals, chlorine, pesticides, nitrates and other unwanted substances.
- High efficiency – 200 gallons per day is an amount suitable for everyday needs in many standard RO installations.
- Wide compatibility – the membrane fits most standard reverse osmosis systems.
- Long service life – lifespan ranges from 24 to 60 months, depending on water quality and intensity of use.
- Easy installation and replacement – the cartridge is designed so that installation in a water filtration system is quick and convenient.
The AC-OM-200 membrane is a reliable solution for users who expect effective filtration without unnecessary costs and want to enjoy clean, healthy water every day.
Filtration efficiency and range of removed contaminants
An osmotic membrane operating in a reverse osmosis system is responsible for very precise filtration at the final stage. It is this element that determines the high quality of purification, which is why it is so important in every reverse osmosis system.

The AC-OM-200 model achieves a minimum contaminant removal efficiency of up to 99%. The separation capacity includes:
- bacteria,
- viruses,
- heavy metals, including lead, mercury and arsenic,
- chlorine,
- pesticides,
- nitrates,
- sulfates,
- organic compounds.
As a result, the membrane is an important component wherever a water filter must provide a high level of purification and stable operating parameters for the entire RO system.
Operation and important usage guidelines
To ensure the osmotic membrane maintains high efficiency and the longest possible service life, it should operate under appropriate conditions of pressure, temperature, and feed water quality. Proper operation has a direct impact on the performance and durability of the cartridge.
The membrane has 0 ppm chlorine tolerance, so it is recommended to use pre-filters that remove chlorine before the water reaches the membrane. This is a very important condition for maintaining its performance and service life.
The membrane service life ranges from 24 to 60 months. The actual operating time depends primarily on the quality of the incoming water and the intensity of use. Final performance is also affected by the degree of contamination in the output water.
* Depending on the degree of contamination in the output water.
200 GPD AC-OM-200 Osmotic Membrane Water Filter Reverse Osmosis EFFICIENT
✅ 200 GPD AC-OM-200 osmotic membrane
The 200 GPD AC-OM-200 osmotic membrane is a key element of filtration in reverse osmosis systems, ensuring excellent drinking water quality.
The membrane capacity is 200 gallons per day (GPD), which corresponds to approximately 760 liters of clean water per day, making it ideal for home and office installations.
✅ Key features:
⭐ Advanced filtration technology: Removes up to 99% of contaminants such as bacteria, viruses, heavy metals, chlorine, pesticides, nitrates and other harmful substances.
⭐ High efficiency: 200 GPD guarantees a large amount of clean water for everyday needs.
⭐ Compatibility: Fits most standard reverse osmosis systems.
⭐ Durability: The membrane service life ranges from 2 to 5 years, depending on water quality and intensity of use.
⭐ Easy installation: Simple installation and replacement in filtration systems.
The AC-OM-200 membrane is a reliable choice for anyone who wants to enjoy clean, healthy water in their home, ensuring the highest filtration quality without unnecessary costs.
Technical parameters:
-
Capacity: 200 GPD (gallons per day) ≈ 760 liters per day *
-
Minimum contaminant removal efficiency: up to 99%
-
Operating pressure range: 2.8 – 6.0 bar
-
Operating temperature range: 4°C – 45°C
-
Minimum operating pressure: 2.8 bar
-
Membrane diameter: 1.8 inches (4.5 cm)
-
Membrane length: 12 inches (30 cm)
-
Water pH range: 3 – 10
-
Chlorine tolerance: 0 ppm (preliminary chlorine removal by pre-filters recommended)
-
Membrane service life: from 24 to 60 months (depending on water quality and intensity of use)
-
Contaminant separation capability: Bacteria, viruses, heavy metals (lead, mercury, arsenic), chlorine, pesticides, nitrates, sulfates, organic compounds
* Depending on the degree of contamination in the output water.

Technical specification
| Parameter | Value |
|---|---|
| Model | AC-OM-200 |
| Product type | Osmotic membrane for reverse osmosis systems |
| Capacity | 200 GPD (gallons per day) ≈ 760 liters per day* |
| Minimum contaminant removal efficiency | Up to 99% |
| Operating pressure range | 2.8–6.0 bar |
| Minimum operating pressure | 2.8 bar |
| Operating temperature range | 4°C–45°C |
| Water pH range | 3–10 |
| Membrane diameter | 1.8 inches (4.5 cm) |
| Membrane length | 12 inches (30 cm) |
| Chlorine tolerance | 0 ppm |
| Membrane service life | From 24 to 60 months, depending on water quality and intensity of use |
| Contaminant separation capability | Bacteria, viruses, heavy metals (lead, mercury, arsenic), chlorine, pesticides, nitrates, sulfates, organic compounds |
| Application | Home and office RO systems |
Questions
What is the AC-OM-200 osmotic membrane used for?
It is a key cartridge in a reverse osmosis system. It is responsible for very precise water filtration and the separation of many contaminants, helping to obtain clean drinking water.
What is the efficiency of this membrane?
The efficiency is 200 GPD, or about 760 liters per day. The actual amount of water obtained may depend on the degree of contamination in the output water and the operating conditions of the installation.
Which contaminants does the membrane remove?
The membrane removes up to 99% of contaminants, including bacteria, viruses, heavy metals such as lead, mercury and arsenic, as well as chlorine, pesticides, nitrates, sulfates and organic compounds.
Does the membrane fit every RO system?
The AC-OM-200 model fits most standard reverse osmosis systems. Before purchase, it is worth comparing the cartridge dimensions and operating parameters with the existing installation.
What operating conditions are required for the membrane?
The recommended operating pressure range is 2.8–6.0 bar, the minimum operating pressure is 2.8 bar, and the operating temperature range is 4°C–45°C. The acceptable water pH range is 3–10.
Why must chlorine be removed before the membrane?
The membrane has a chlorine tolerance of 0 ppm. This means that pre-filters removing chlorine should be used before operation to avoid reducing filtration efficiency and shortening the cartridge service life.
How long can the AC-OM-200 membrane be used?
The membrane service life ranges from 24 to 60 months. The operating time depends on the quality of the feed water, proper operation of the pre-filters, and the intensity of system use.
Is membrane installation complicated?
No, replacement and installation of the membrane are simple in most standard RO filtration systems. However, it is important to ensure compatibility of dimensions and parameters with the device you have.
What are the membrane dimensions?
The membrane has a diameter of 1.8 inches, or 4.5 cm, and a length of 12 inches, or 30 cm. These dimensions are important when matching the cartridge to the housing in a reverse osmosis system.