AC-OM-100 100 GPD osmotic membrane
AC-OM-100 Osmotic Membrane 100 GPD for reverse osmosis (R.O.) systems. The TFC semi-permeable membrane in the form of a spiral coil is Read moreShow less
AC-OM-100 Osmotic Membrane 100 GPD for reverse osmosis (R.O.) systems. The TFC semi-permeable membrane in the form of a spiral coil is a key element of molecular filtration, limiting the penetration of organic and inorganic contaminants as well as dissolved salts. Performance up to 100 GPD (approx. 370 l/24 h) , operating range 2-42°C and 2.8-6 bar .
Benefits
Specifications
- Wysokość wkładu
- 12"
- Temperatura pracy
- 2°C - 42°C
- Żywotność
- do 84 miesięcy*
- Średnica wkładu
- 2"
- Compatibility
- Universal RO systems
- Height
- 304.8 mm
View full specifications
- Maximum working pressure
- 6 bar
- Membrane capacity
- 100 GPD
- Membrane size
- 1812
- Minimum working pressure
- 2.8 bar
- Model
- AC-OM-100
- Product type
- RO membrane
Description
AC-OM-100 100 GPD osmotic membrane is a key cartridge for installations such as reverse osmosis, an osmotic filter, and a reverse osmosis system. The semi-permeable TFC membrane is responsible for the most precise stage of water purification, limiting the passage of organic and inorganic contaminants, dissolved salts, heavy metals, and other undesirable substances. The AC-OM-100 model offers a capacity of up to 100 GPD, or approximately 370 l/24 h, operates within a range of 2-42°C and at a pressure of 2.8-6 bar, making it well suited as a component of a household water filtration system and a water treatment solution.

TFC membrane for precise molecular filtration
The AC-OM-100 osmotic membrane is the most important part of an R.O. molecular filtration system. It is at this stage that the most precise water purification takes place, characteristic of reverse osmosis technology.
The membrane structure is based on several thin layers connected in the form of a spiral wound element. This solution is also known as a thin-film composite, i.e. a TFC membrane. The semi-permeable material creates an effective barrier against many groups of contaminants present in water.
How does the AC-OM-100 osmotic membrane work?
In a reverse osmosis system, the membrane is responsible for separating water molecules from a wide spectrum of contaminants. Thanks to its semi-permeable structure, it forms a barrier against:
- organic contaminants,
- inorganic contaminants,
- dissolved solids in water,
- heavy metals,
- radioactive elements,
- toxic and carcinogenic chemical compounds.
R.O. technology is considered one of the most precise and efficient water purification methods used in household filtration systems. For this reason, the osmotic membrane remains the heart of the entire system and has a direct impact on the quality of treated water.
Contaminant reduction range
The molecular filtration system using the AC-OM-100 membrane limits the passage of many undesirable substances. Below is the full list of reduction parameters maintained for this model:
- chlorine > 97%
- radioactive elements > 90%
- calcium and magnesium (hardness) > 96%
- liquid fuels > 98%
- nitrates and nitrites > 83%
- aromatic hydrocarbons > 98%
- heavy metals (e.g. lead, mercury, etc.) > 97%
- bacteria > 99%
Why is it an important element of a reverse osmosis system?
In practice, it is the osmotic membrane that is responsible for the final effectiveness of an R.O. set. A properly selected reverse osmosis filter helps reduce the amount of substances affecting the taste, smell, and overall quality of water.
The AC-OM-100 model can be a good choice for users who expect high filtration precision, stable operation, and capacity suitable for household use. A capacity of up to 100 GPD makes the membrane suitable for everyday operation in installations preparing water for drinking and kitchen use.
Important: the maximum membrane lifespan is up to 7 years and depends on the degree of contamination of the feed water. Lifespan is also affected by the installation's operating conditions, including feed water quality, temperature, and working pressure.
Operation and selection
The AC-OM-100 membrane is designed to operate within a specific temperature and pressure range. Maintaining the correct operating parameters is important for filtration effectiveness and cartridge durability.
When selecting a membrane for a water filtration system, it is worth paying attention to dimensional compatibility and the device's operating parameters. This model uses a standard design with a height of 12 inches and a diameter of 2 inches.
If the membrane operates in a reverse osmosis system used regularly, maintaining proper operating conditions helps preserve high filtration efficiency and stable daily output.
* Depending on the degree of contamination of the feed water.
Additional important information
- Diameter: 2"
Technical specification
| Parameter | Value |
|---|---|
| Model | AC-OM-100 |
| Membrane type | TFC, thin-film composite, spiral wound |
| Height | 12" |
| Capacity | 100 GPD / up to 370 L/24h |
| Operating temperature | 2-42 °C |
| Operating pressure | 2.8 - 6 bar Max |
| Maximum lifespan | up to 7 years * |
FAQ
What is the AC-OM-100 100 GPD osmotic membrane used for?
It is a basic component of a reverse osmosis system responsible for molecular filtration. The membrane separates water from many organic and inorganic contaminants, dissolved salts, and other undesirable substances.
What does a capacity of 100 GPD mean?
100 GPD means a capacity of up to approximately 100 gallons per day, which is about 370 liters over 24 hours. This parameter defines the maximum daily water production under appropriate operating conditions.
What contaminants does this membrane reduce?
The AC-OM-100 model helps reduce, among other things, chlorine, radioactive elements, calcium and magnesium responsible for water hardness, liquid fuels, nitrates and nitrites, aromatic hydrocarbons, heavy metals, and bacteria, in accordance with the stated reduction levels.
Is this membrane suitable for a household water filter?
Yes, the membrane is intended for reverse osmosis systems used as a household water filtration system. Its operating parameters and capacity make it a suitable solution for everyday water treatment for household needs.
Within what temperature range can the membrane operate?
The operating temperature range is from 2 to 42°C. Operation within this range supports proper membrane function and helps maintain its effectiveness.
What operating pressure is required?
The membrane operates at a pressure of 2.8 to 6 bar. Maintaining the correct pressure affects performance and the proper operation of the entire reverse osmosis system.
What are the dimensions of the AC-OM-100 membrane?
The model has a height of 12 inches and a diameter of 2 inches. These are important parameters when checking compatibility with the housing and system configuration.
How long can the membrane operate?
The maximum membrane lifespan is up to 7 years. The actual service life depends on the degree of contamination of the feed water and the operating conditions.